Skip to content

Heat Trace Control Panels

Heat-trace control panels and controllers manage heating circuits using the sensing and switching functions specified for each product. Select controls to match the cable system, supply voltage, circuit requirements, and installation environment.

Review each product for its sensor requirements, enclosure rating, electrical limits, and included protection features. Use the cable and controller documentation together when planning the system.

Browse the controls and accessories below, or compare control zones, sensors, protection and monitoring features before selecting a model.

Showing all 26 results

Choosing heat-trace control panels and controllers

Start with the heating application, independently controlled circuits, sensing method and electrical load. This catalog also includes sensors, wire and separate protection equipment; those components perform different jobs from a temperature controller.

Panels, controllers and control zones

A packaged panel combines its specified control, switching and protection components in an enclosure. An individual controller may require additional switching or protection equipment. Check the panel drawing and the number of independently controlled outputs.

For one zone, review single-point models; for two independently controlled heating zones, compare GPT-230 or ITC2. Additional sensor inputs or networked controllers do not automatically make one device a multizone panel.

Ambient sensing, line sensing and sensor inputs

Ambient sensing measures surrounding air; line sensing measures the pipe or vessel. Select sensor position and control settings for the application, then match the exact sensor input and wiring.

Thermistors, Pt100 RTDs and thermocouples require different inputs; thermistor resistance also varies by controller family. Compare the ETI25076 GPT/FPT replacement sensor and three-wire 100-ohm RTD against the selected manual. Mechanical thermostats use their specified stem or bulb-and-capillary sensing.

Ground-fault protection and fault response

Ground-fault equipment protection, overcurrent protection and temperature control are separate functions. Check whether the exact model and supply arrangement provide the required protection or need an upstream device. A product labeled GFI is not automatically a personnel-protection GFCI.

Temperature, sensor and ground-fault alarms may have different trip, reset and heater-output behavior. Review the configured fault response; an alarm indication does not always disconnect heater power. Separate ground-fault equipment has its own voltage and circuit limits.

Temperature monitoring, communications and environment

Compare temperature display, low/high-temperature or sensor-failure alarms, and remote alarm outputs where documented. A dry-contact alarm output is different from Wi-Fi, Ethernet or a building-network interface. Verify the full model, communications option, gateway and firmware needed for remote monitoring.

Match enclosure and operating conditions to moisture, corrosion and ambient exposure. NEMA/IP weather resistance alone does not establish hazardous-location approval. Use the exact approved model and installation conditions for a classified area.

Compare documented controller features

Model-specific differences to check alongside the product documentation.
Controller familyControl points and sensingProtection and monitoring distinctions
FPT-130 Single-circuit freeze protection with thermistor sensing. Equipment ground-fault protection and alarms; ordinary locations. The reviewed FPT model is not an RTD controller.
GPT-130 / GPT-230 One / two control points; included thermistor or supported three-wire Pt100 RTD configuration. Temperature, current and ground-fault monitoring with equipment protection. Check alarm and heater-trip configuration; select GPT-230 for two independent channels.
FRIO S1-A Connected single-circuit control with thermistor or supported Pt100 RTD sensing. Wi-Fi/Ethernet and equipment ground-fault protection. RS-485 Modbus is documented for S1-A-0002; BACnet requires a separate gateway. Confirm the full supplied model.
FRIO S1-B Connected single-circuit control. Confirm sensor inputs for the supplied hardware revision. Wi-Fi and equipment ground-fault protection are documented. Verify sensor and network options against the full model and current FRIO documentation; confirm the applicable hardware and manual revision.
ITC1 / ITC2 One / two circuits with three-wire Pt100 RTD sensing. Check the manufacturer's voltage-dependent upstream GFEP requirements. Modbus RTU/RS-485 is documented; Ethernet requires the matching ordered option. Verify communications and location approvals for the exact unit.
DTS-HAZ Digital thermostat with RTD input and temperature/sensor alarms. Review its classified-location and alarm-supply variant. Integrated ground-fault protection is not established by the reviewed DTS documentation; specify the required protection separately.
CET-GF Electronic thermostat with Pt100 RTD sensing. Integrated equipment ground-fault protection and alarm output for ordinary locations. Confirm the specified cable compatibility and trip/latch settings.

Existing panels and legacy model identification

The HTP30 panel uses its documented Type J thermocouple arrangement. Retained ProTrace ambient-sensing and line-sensing model pages help identify existing SZ installations. Confirm availability and the exact protection variant before ordering a phased-out model or selecting a replacement.

Match the control to the heat-trace system

For self-regulating cable or constant-wattage cable, verify supply voltage, load and startup conditions, switching arrangement, sensing and required approvals. A controller's presence in this catalog does not establish compatibility with every cable or application.

For a panel, multizone installation or monitoring integration, request controls application help with the circuit count, cable details, sensors, environment and communications requirements.

Technical references: FPT-130 data sheet (PDF), GPT-130 data sheet (PDF) and GPT-230 data sheet (PDF).