Heat Trace Control Panels
Heat-trace control panels and controllers manage heating circuits using the sensing and switching functions specified for each product. Select controls to match the cable system, supply voltage, circuit requirements, and installation environment.
Review each product for its sensor requirements, enclosure rating, electrical limits, and included protection features. Use the cable and controller documentation together when planning the system.
Browse the controls and accessories below, or compare control zones, sensors, protection and monitoring features before selecting a model.
Showing all 26 results
-

Single Point Freeze Protection Heat Trace Controller
SKU FPT-130
$825.00 View Product -

Single Point General Purpose Heat Trace Controller
SKU GPT-130
$1,100.00 View Product -

Dual Point General Purpose Heat Trace Controller
SKU GPT-230
$1,785.00 View Product -

S1-B-2002 Heat Trace Controller – Thermistor only, No RTD, No Modbus
SKU S1-B-2002
$1,480.85 View Product -

S1-A Heat Trace Controller – RTD & Thermistor With Modbus and BACnet Compatibility
SKU S1-A
$1,944.35 View Product -

Hazardous Area – Single Zone – Digital Heat Trace Controller Class 1, Division 2
SKU ITC1
$2,100.00 View Product -

Hazardous Area – Dual Zone – Digital Heat Trace Controller Class 1, Division 2
SKU ITC2
$3,680.00 View Product -

Hazardous Area DTS-HAZ Heat Trace Digital Thermostat Class 1, Division 2
SKU DTS-HAZ
$1,933.33 View Product -

Chromalox CET-GF Commercial Heat Trace Electronic Thermostat with GFEP
SKU CET-GF
$1,511.00 View Product -

TSW150 Weatherproof Digital Temperature Switch – 90–255 VAC
SKU TSW150
$225.00 View Product -

Protrace Series With Soft Start Ambient Sensing Heat Trace Controller
SKU SZAS
$1,646.75 View Product -

Protrace Series With Soft Start Ambient Sensing Heat Trace Controller with GFI
SKU SZASP
$1,852.45 View Product -

Protrace Series With Soft Start Line Sensing Heat Trace Controller
SKU SZLS
$1,646.75 View Product -

Protrace Series With Soft Start Line Sensing Heat Trace Controller with GFI
SKU SZLSP
$1,852.45 View Product -

Ambient Sensing Thermostat NEMA 4X
SKU 1660-18911
$447.42 View Product -

Line Sensing Thermostat NEMA 4X
SKU 1660-13A11
Harsh / corrosive environment$519.00 View Product -

Ambient Sensing Thermostat FM Class 1 Div 1
SKU 1660-18912
Hazardous location$590.00 View Product -

Line Sensing Thermostat FM Class 1 Div 1
SKU 1660-13A12
Harsh / corrosive environmentHazardous location$660.00 View Product -

Ambient Air Temperature Sensor
SKU ASN4
Harsh / corrosive environment$143.75 View Product -

Ground Fault Protection Unit – Required By UL
SKU GF
Harsh / corrosive environment$166.75 View Product -

HTP30 Basic Heat Trace Control Panel With GFI
SKU HTP30
$925.00 View Product -

20′ 100 ohm 3 wire RTD rated to 450F
SKU FPRTD305A1ZRR24OTO-E
$105.00 View Product -

GPT/FPT Replacement Temperature Sensor – ETI25076
SKU ETI25076
$152.40 View Product -

18 AWG 3-Conductor FEP RTD Sensor Wire – Sold by the Foot
SKU A29-180330BCR
$1.95 per ft. View Product -

24 AWG 3-Conductor FEP RTD Sensor Wire – Sold by the Foot
SKU RTD-FEP-24N-3
$1.35 per ft. View Product -

Type J 20 AWG Thermocouple Wire – Sold by the Foot
SKU A30-201020
$0.65 per ft. View Product
Choosing heat-trace control panels and controllers
Start with the heating application, independently controlled circuits, sensing method and electrical load. This catalog also includes sensors, wire and separate protection equipment; those components perform different jobs from a temperature controller.
Panels, controllers and control zones
A packaged panel combines its specified control, switching and protection components in an enclosure. An individual controller may require additional switching or protection equipment. Check the panel drawing and the number of independently controlled outputs.
For one zone, review single-point models; for two independently controlled heating zones, compare GPT-230 or ITC2. Additional sensor inputs or networked controllers do not automatically make one device a multizone panel.
Ambient sensing, line sensing and sensor inputs
Ambient sensing measures surrounding air; line sensing measures the pipe or vessel. Select sensor position and control settings for the application, then match the exact sensor input and wiring.
Thermistors, Pt100 RTDs and thermocouples require different inputs; thermistor resistance also varies by controller family. Compare the ETI25076 GPT/FPT replacement sensor and three-wire 100-ohm RTD against the selected manual. Mechanical thermostats use their specified stem or bulb-and-capillary sensing.
Ground-fault protection and fault response
Ground-fault equipment protection, overcurrent protection and temperature control are separate functions. Check whether the exact model and supply arrangement provide the required protection or need an upstream device. A product labeled GFI is not automatically a personnel-protection GFCI.
Temperature, sensor and ground-fault alarms may have different trip, reset and heater-output behavior. Review the configured fault response; an alarm indication does not always disconnect heater power. Separate ground-fault equipment has its own voltage and circuit limits.
Temperature monitoring, communications and environment
Compare temperature display, low/high-temperature or sensor-failure alarms, and remote alarm outputs where documented. A dry-contact alarm output is different from Wi-Fi, Ethernet or a building-network interface. Verify the full model, communications option, gateway and firmware needed for remote monitoring.
Match enclosure and operating conditions to moisture, corrosion and ambient exposure. NEMA/IP weather resistance alone does not establish hazardous-location approval. Use the exact approved model and installation conditions for a classified area.
Compare documented controller features
| Controller family | Control points and sensing | Protection and monitoring distinctions |
|---|---|---|
| FPT-130 | Single-circuit freeze protection with thermistor sensing. | Equipment ground-fault protection and alarms; ordinary locations. The reviewed FPT model is not an RTD controller. |
| GPT-130 / GPT-230 | One / two control points; included thermistor or supported three-wire Pt100 RTD configuration. | Temperature, current and ground-fault monitoring with equipment protection. Check alarm and heater-trip configuration; select GPT-230 for two independent channels. |
| FRIO S1-A | Connected single-circuit control with thermistor or supported Pt100 RTD sensing. | Wi-Fi/Ethernet and equipment ground-fault protection. RS-485 Modbus is documented for S1-A-0002; BACnet requires a separate gateway. Confirm the full supplied model. |
| FRIO S1-B | Connected single-circuit control. Confirm sensor inputs for the supplied hardware revision. | Wi-Fi and equipment ground-fault protection are documented. Verify sensor and network options against the full model and current FRIO documentation; confirm the applicable hardware and manual revision. |
| ITC1 / ITC2 | One / two circuits with three-wire Pt100 RTD sensing. | Check the manufacturer's voltage-dependent upstream GFEP requirements. Modbus RTU/RS-485 is documented; Ethernet requires the matching ordered option. Verify communications and location approvals for the exact unit. |
| DTS-HAZ | Digital thermostat with RTD input and temperature/sensor alarms. | Review its classified-location and alarm-supply variant. Integrated ground-fault protection is not established by the reviewed DTS documentation; specify the required protection separately. |
| CET-GF | Electronic thermostat with Pt100 RTD sensing. | Integrated equipment ground-fault protection and alarm output for ordinary locations. Confirm the specified cable compatibility and trip/latch settings. |
Existing panels and legacy model identification
The HTP30 panel uses its documented Type J thermocouple arrangement. Retained ProTrace ambient-sensing and line-sensing model pages help identify existing SZ installations. Confirm availability and the exact protection variant before ordering a phased-out model or selecting a replacement.
Match the control to the heat-trace system
For self-regulating cable or constant-wattage cable, verify supply voltage, load and startup conditions, switching arrangement, sensing and required approvals. A controller's presence in this catalog does not establish compatibility with every cable or application.
For a panel, multizone installation or monitoring integration, request controls application help with the circuit count, cable details, sensors, environment and communications requirements.
Technical references: FPT-130 data sheet (PDF), GPT-130 data sheet (PDF) and GPT-230 data sheet (PDF).