10 Watt per Foot 240 Volt Self-Regulating Fire Sprinkler Heat Trace Cable – Tinned Copper Braid + Thermoplastic Rubber Overjacket – CPR

Part Number: CPR-10-2CR

Availability: Ships in 3-5 days

$13.28 per ft

Installation Kits, Accessories & ControllersInstallation Kits, Accessories & Controllers →

10 W/ft self-regulating commercial heat-trace cable for pipe freeze protection and other approved applications. 208–277 V, field-cuttable, with CR protective overjacket. Part of the listed Fire Sprinkler Pipe Freeze Protection system when selected and installed with the required approved components on metallic sprinkler piping. Sold by the foot.

Voltage
208–277 V
Wattage
10 Watt
Enter how many feet you want to order Enter the total footage you want to purchase.

Overview

CPR-10-2CR is a self-regulating commercial heat-trace cable. As pipe temperature falls, the conductive polymer core increases heat output; as temperature rises, output decreases. The cable can be field cut to the required length within the documented maximum circuit-length limit for the application and electrical conditions.

This Model

SKU CPR-10-2CR
Nominal output 10 W/ft at 50°F
Voltage family 208–277 V
Outer jacket CR — TPR overjacket over braid for protection against certain inorganic chemical solutions
Approximate cable size 0.47 in W × 0.20 in H
Minimum bend radius 1-1/8 in
Maximum process maintenance 150°F / 65°C, power on
Maximum continuous exposure 185°F / 85°C, power off
Buying format Sold by the foot

Fire Sprinkler Pipe Freeze Protection

This exact CPR10 model is in the documented Fire Sprinkler Pipe Freeze Protection cable family when selected from the published tables and installed on metallic piping with the required approved connections, controls, sensors, attachment accessories, insulation and cover. The sprinkler listing does not extend to plastic piping.

Typical Supported Applications

  • Commercial pipe freeze protection for potable and non-potable piping
  • Sanitary, storm, greasy-waste and diesel-fuel piping where the selected system is suitable
  • Fire-sprinkler piping under the sprinkler-specific limits above
  • Roof and gutter de-icing
  • Freezer frost-heave prevention and floor warming where designed for that application

Application-specific design and circuit limits differ. Do not reuse a circuit table from another application.

Cable Construction

  1. 16 AWG nickel-plated copper bus conductors carry the circuit current.
  2. Self-regulating polymer matrix changes resistance and heat output with local temperature.
  3. Flame-retardant polyolefin primary jacket electrically insulates the heating matrix and provides documented water/inorganic-solution resistance.
  4. Tinned-copper braid adds mechanical protection and provides a grounding path.
  5. CR outer jacket — TPR overjacket over braid for protection against certain inorganic chemical solutions.

Do not broaden chemical compatibility beyond the supplied datasheet; confirm the actual exposure before selecting CR or CT.

Electrical Design

Maximum circuit length varies by CPR wattage, voltage family, breaker rating, startup temperature and application. Ground-fault equipment protection is required. For sprinkler work, use the fire-sprinkler-specific design tables rather than the generic CPR pipe-freeze, roof/gutter or grease-maintenance tables.

Required System Components

A complete sprinkler installation requires compatible power connection, tee/splice components where the route branches or joins, approved end seals, the documented ITC-FS/RTBC-FS control and overtemperature system, sensors, fiberglass attachment tape, warning labels, and non-combustible insulation with a sealed non-combustible exterior cover.

Selection information does not replace product installation instructions, electrical design, or fire-protection engineering.

Complete the Cable System

Connection, installation, control, and sensor products for CPR cable.

Connection and installation accessories

Controllers and thermostats

Fire-sprinkler installations use the documented ITC-FS and RTBC-FS control system. RTAS is an option for other CPR applications.

Sensors and wiring