This ProTherm 1¼ in NPT screw-plug immersion heater uses a Steel plug, 3 heating elements, and a nominal 20-23 W/in² watt-density family. It is configured to order through the selections above; the validated combination determines the finished ProTherm PT part number.
Technical specifications
| Base family SKU | PTFM2 |
|---|---|
| NPT connection | 1¼ in NPT |
| Screw-plug material | Steel |
| Element sheath | Incoloy 840 |
| Nominal watt density | 20-23 W/in² |
| Element count | 3 |
| Available output | 500–3,000 W |
| Available voltage | 120 / 240 VAC |
| Phase | Single phase |
| Selectable immersion range | 6 ¼–36 ⅝ in |
| Standard enclosure | NEMA 1; configured enclosure and thermostat options are shown above |
| Terminals | #10-32 plate terminals with screws |
| Published plug dimensions | E 1⅜ in; F 9⁄16 in; H 1¾ in |
Dimensional reference
E, F and H plug dimensions
| Plug material | E | F | H |
|---|---|---|---|
| Brass | 1¼ in | 3⁄8 in | 1¾ in |
| Steel or stainless steel | 1⅜ in | 9⁄16 in | 1¾ in |
Construction and features
- Incoloy 840 element sheath with high-purity compacted magnesium oxide insulation.
- Nickel-chromium resistance wire and fusion-welded pin-to-resistance-wire junction.
- The Incoloy 840 elements are welded to the steel screw plug for joint strength and corrosion protection.
- Moisture-sealed element ends; sealing construction is selected for the intended medium.
- Accessible NEMA 1 terminal housing with fixed conduit support.
- Spacer supports are used on applicable multiple-element units with longer immersed lengths.
- Applicable units may be configured with thermostat, thermowell, and alternate enclosure options shown in the product selector.
Typical applications
- Oils and compatible alkali solutions
- Reservoirs, process tanks, and industrial equipment requiring lower surface loading
Why watt density matters
This lower-watt-density family reduces surface loading and is intended for media such as oils or other temperature-sensitive services when compatibility is confirmed. Watt density is one part of heater selection; also verify sheath and plug compatibility, liquid level, circulation, operating temperature, and controls.
Configuration
Select the required output or immersion length, voltage, and available terminal-housing or control options using the configurator above. HEP’s explicit mapping validates the combination and displays the finished ProTherm part number; the family SKU is not the finished ordering number.
Engineering and application support
Confirm chemical compatibility, allowable watt density, required immersion, voltage, phase, enclosure rating, and control strategy before installation. Keep the heated section immersed during operation. For uncertain media or non-standard requirements, use the Screw Plug Heater Engineering Selector or contact HEP Engineering.