Cartridge heater 3/4 x 16 inch 240V 1600W with 26 inch swaged in leads.
Verified specifications
| Manufacturer | Protherm |
|---|---|
| Manufacturer Part Number | TD75160A-26S |
Reference image: Product image is for reference only. Actual heater configuration, lead style, dimensions, and fittings may vary by part number. Refer to the product specifications for the exact configuration.
Temperature control
Browse controllers and control panels for your cartridge heater system.
Temperature feedback
Match sensor type, probe dimensions, mounting, lead construction, and temperature range to the process.
Part Number: TD75160A-26S
Availability: Ships in 2–3 days
$251.62
3/4 dia. x 16 inch insertion 240V 1600W with 26 inch swaged-in leads.
Custom heaters are non-returnable.
Cartridge heater 3/4 x 16 inch 240V 1600W with 26 inch swaged in leads.
| Manufacturer | Protherm |
|---|---|
| Manufacturer Part Number | TD75160A-26S |
Engineering reference
Minimum and maximum diameters are in inches. Lead wire sizes are AWG.
| Nominal Diameter | Minimum Diameter (in) | Maximum Diameter (in) | Standard Lead Wire (AWG) | Max. Amps with Standard Lead | Max. Lead Wire Size (AWG) | Maximum Amps | Maximum Volts |
|---|---|---|---|---|---|---|---|
| 1/8 in | .119 | .124 | 24 | 3.6 | 24 | 3.6 | 240 |
| 1/4 in | .244 | .249 | 24 | 6 | 22 | 9 | 300 |
| 6.5 mm | .250 | .255 | 24 | 6 | 22 | 9 | 300 |
| 5/16 in | .306 | .311 | 24 | 6 | 22 | 9 | 300 |
| 8 mm | .309 | .314 | 24 | 6 | 22 | 9 | 300 |
| 3/8 in | .369 | .374 | 22 | 9 | 18 | 15 | 480 |
| 10 mm | .388 | .393 | 22 | 9 | 18 | 15 | 480 |
| 12 mm | .466 | .471 | 22 | 9 | 18 | 15 | 480 |
| 12.5 mm | .486 | .491 | 22 | 9 | 18 | 15 | 480 |
| 1/2 in | .494 | .499 | 22 | 9 | 18 | 15 | 480 |
| 13 mm | .506 | .511 | 22 | 9 | 18 | 15 | 480 |
| 17/32 in | .525 | .530 | 22 | 9 | 18 | 15 | 480 |
| 14 mm | .545 | .550 | 18 | 15 | 14 | 26 | 480 |
| 5/8 in | .619 | .624 | 18 | 15 | 14 | 26 | 480 |
| 16 mm | .624 | .629 | 18 | 15 | 14 | 26 | 480 |
| 17 mm | .663 | .668 | 18 | 15 | 14 | 26 | 480 |
| 11/16 in | .682 | .687 | 18 | 15 | 14 | 26 | 480 |
| 19 mm | .742 | .747 | 18 | 15 | 14 | 26 | 480 |
| 3/4 in | .744 | .749 | 18 | 15 | 14 | 26 | 480 |
| 25 mm | .978 | .983 | 18 | 15 | 14 | 26 | 480 |
| 1 in | .994 | .999 | 18 | 15 | 14 | 26 | 480 |
A loose fit creates a larger thermal gap, which reduces heat transfer and can shorten heater life.
Clearance = hole diameter − heater diameter
Clearance is the difference between the finished hole diameter and the actual heater diameter. Evaluate fit and watt density together; an acceptable watt density depends partly on how effectively heat moves into the workpiece.
Watt density describes the heater load over its heated sheath area. Use heated length—not necessarily overall or insertion length—when confirmed for the design.
Watt Density = Wattage ÷ (Heated Length × Diameter × 3.14)
| Hole clearance (in) | 1200°F | 1000°F | 800°F | 600°F | 400°F | 200°F |
|---|---|---|---|---|---|---|
| 0.002 | 140 | 270 | 300 | 300 | 300 | 300 |
| 0.003 | 120 | 205 | 295 | 300 | 300 | 300 |
| 0.004 | 100 | 175 | 240 | 300 | 300 | 300 |
| 0.005 | 90 | 145 | 200 | 285 | 300 | 300 |
| 0.007 | 70 | 100 | 150 | 200 | 250 | 300 |
| 0.010 | 60 | 90 | 110 | 150 | 200 | 225 |
| 0.015 | 50 | 75 | 95 | 110 | 140 | 165 |
| 0.030 | 40 | 60 | 80 | 90 | 100 | 110 |
| 0.060 | 30 | 40 | 50 | 55 | 65 | 65 |
| 0.100 | 25 | 35 | 45 | 50 | 50 | 50 |
Values are application guidelines. Proper heater sizing depends on fit, operating temperature, cycling, and the heated material.
Termination choice affects routing, abrasion resistance, flexing, temperature exposure, and the unheated lead-end region.
Representative product images are shown. The finished heater may not look exactly like the image because dimensions and construction vary by configuration.

Useful where leads may move or must bend sharply near the heater exit.
This product’s lead style
Useful where installation and routing space is limited.

Provides abrasion protection while allowing a tighter bend radius than flexible conduit.

Combines braid protection with compact routing.

Provides increased abrasion and mechanical protection, with less flexibility than braid.

Combines compact routing with increased mechanical protection.
Conduit and braid are supplied 2" shorter than the selected lead length.
Crimped-on leads keep lead-end unheated length small for high-temperature exits, but are less suitable for repeated flexing or sharp bends near the heater.
Convoluted conduit and other special protection can be specified for relevant custom applications; continuous flexing still requires engineering review.
The standard choice for oxidation resistance in many applications. Consider Incoloy for service above 1200°F.
Often preferred for immersion service, particularly tap water, and other environments needing improved corrosion resistance.
Recommended for higher-temperature service above 1200°F. Below that temperature it may not improve performance.
This is application guidance, not a universal chemical-compatibility guarantee.
| Application | 304 SS | 316 SS | Incoloy | Max W/in² | Max °F |
|---|---|---|---|---|---|
| Air to 1500°F | Excellent | Excellent | Excellent | ||
| Air to 1600°F | Good | Good | Excellent | ||
| Air to 1800°F | Not recommended | Not recommended | Good | ||
| Acetic acid | Fair | Good | Fair | 40 | 180 |
| Acetone | Excellent | Excellent | Excellent | 20 | 130 |
| Alcohol | Fair | Excellent | Excellent | 25 | 212 |
| Asphalt | Excellent | Excellent | Excellent | 4–10 | 200–500 |
| Caustic soda, 10% | Excellent | Excellent | Excellent | 100 | 210 |
| Ethylene glycol | Fair | Fair | Fair | 30 | |
| Glycerin | Excellent | Excellent | Excellent | 10 | 500 |
| Nitric acid, 30% max | Fair | Fair | Not recommended | 20 | 167 |
| Oil, SAE 30 | Excellent | Excellent | Excellent | 20 | 250 |
| Oil, SAE 50 | Excellent | Excellent | Excellent | 10–15 | 250 |
| Steam at 300°F | Excellent | Excellent | Excellent | 30 | 300 |
| Steam at 500°F | Excellent | Excellent | Excellent | 25 | 500 |
| Water, distilled | Excellent | Excellent | Excellent | 300 | 212 |
| Water, tap | Fair | Excellent | Excellent | 300 | 212 |
AFitting lengthB
Representative product images. Actual proportions vary with heater diameter, fitting size, and flange dimensions.
| Heater diameter | 1/4 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|
| NPT thread | 1/8 | 1/4 | 3/8 | 1/2 | 3/4 | 1 |
| Brass A | .57 | .70 | .74 | .80 | .92 | 1.30 |
| Brass B | .43 | .56 | .69 | .87 | 1.06 | 1.44 |
| Stainless A | .62 | .76 | .77 | .84 | .96 | 1.27 |
| Stainless B | .46 | .56 | .67 | .87 | 1.06 | 1.37 |
| Heater diameter | 1/4 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|
| NPT thread | 1/8 | 1/4 | 3/8 | 1/2 | 3/4 | 1 |
| Brass A | .98 | 1.13 | 1.25 | 1.53 | 1.72 | 2.35 |
| Brass B | .43 | .56 | .69 | .87 | 1.06 | 1.37 |
| Stainless A | .98 | 1.13 | 1.25 | 1.53 | 1.72 | Call |
| Stainless B | .43 | .56 | .68 | .87 | 1.06 | Call |
| Flange OD | Compatible heater diameters | Hole spacing | Hole size |
|---|---|---|---|
| 1 in | 1/4, 5/16, 3/8, 1/2 in | 3/4 in | .14 in |
| 1-1/2 in | 1/4, 5/16, 3/8, 1/2, 5/8, 3/4 in | 1-1/8 in | .16 in |
| 2 in | 1/2, 5/8, 3/4, 1 in | 1-1/2 in | .20 in |
Always distinguish insertion length from overall length. Many terminations also require an unheated lead-end section; right-angle styles add an extension beyond the heater body.
| Heater length | 1/4 in | 5/16 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|---|
| Under 3 in | .20 | .20 | .25 | .30 | .39 | .39 | .61 |
| Over 3 in | .81 | .79 | .84 | .84 | 1.01 | 1.00 | 1.27 |
| Heater length | 1/4 in | 5/16 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|---|
| Under 3 in | .20 | .20 | .25 | .29 | .54 | .54 | .74 |
| Over 3 in | .20 | .20 | .25 | .29 | .54 | .54 | .81 |
| Heater length | 1/4 in | 5/16 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|---|
| Under 3 in | .20 | .20 | .25 | .29 | .39 | .39 | .24 |
| Over 3 in | .81 | .79 | .84 | .84 | 1.01 | 1.00 | .31 |
| Extension length | .25 | .25 | .31 | .37 | .37 | .37 | .75 |
| Heater length | 1/4 in | 5/16 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|---|
| Under 3 in | .25 | .20 | .35 | .29 | .39 | .39 | .54 |
| Over 3 in | .86 | .79 | .94 | .84 | 1.01 | 1.00 | 1.20 |
| Heater length | 1/4 in | 5/16 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|---|
| Under 3 in | .20 | .20 | .25 | .29 | .39 | .39 | .24 |
| Over 3 in | .81 | .79 | .84 | .84 | 1.01 | 1.00 | .31 |
| Extension length | .31 | .31 | .37 | .37 | .44 | .44 | .75 |
| Heater length | 1/4 in | 5/16 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|---|
| Under 3 in | .62 | .60 | .30 | .23 | .39 | .39 | .54 |
| Over 3 in | 1.23 | 1.20 | .89 | .84 | 1.01 | 1.00 | 1.20 |
| Conduit OD | .25 | .303 | .303 | .303 | .37 | .48 | .48 |
| Heater length | 1/4 in | 5/16 in | 3/8 in | 1/2 in | 5/8 in | 3/4 in | 1 in |
|---|---|---|---|---|---|---|---|
| Under 3 in | .55 | .60 | .65 | .70 | .90 | .80 | .24 |
| Over 3 in | .81 | .79 | .84 | .84 | 1.01 | 1.00 | .31 |
| Extension length | .31 | .37 | .37 | .37 | .44 | .44 | .75 |
| Conduit OD | .25 | .25 | .33 | .37 | .37 | .37 | .37 |
Swaging reduces heater diameter and causes predictable but variable length growth. Longer heaters can need special consideration. Standard trimming can remove only unheated portions, so an exact finished length may require a designed cold section or a custom length-control construction. Contact engineering for unusual length, flange-location, or minimal-unheated-section requirements.
Appropriate temperature control reduces overheating risk and unnecessary cycling. Match the controller, power switching, sensor, voltage, current, and control method to the application.

Recommended Temperature Controller
Suitable for a single-zone application only when this heater/load remains within the controller’s electrical capacity and the selected sensor and control configuration are appropriate.
View ControllerNeed Temperature Feedback?
Cartridge-heater systems commonly use a thermocouple or another temperature sensor. A separate sensor measures the process unless the heater was specifically designed with an internal thermocouple.
There is no single standard life. Service life depends on the application, operating temperature, watt density, cycling, hole fit, and contamination.
The appropriate limit depends on the sheath material and application conditions. Select the sheath for the process environment and obtain engineering review for high-temperature or corrosive service.
The heated material, application temperature, and hole fit all affect allowable watt density. A tighter fit generally improves heat transfer; watt density and fit must be evaluated together.
Thermal expansion is usually not a primary fit issue because the heated part expands too. Allowance may still be important in constrained assemblies or unusual materials, so consult engineering when movement is critical.
Prevent contamination at the lead end, avoid unnecessary cycling, size the heater correctly, avoid excess wattage, maintain proper hole fit, and use appropriate temperature control.
Proper temperature control helps reduce overheating and excessive cycling. The controller, sensor, voltage, current, and control method must all suit the application.
Explore nearby catalog products. Each card shows only what changes from the heater above; confirm the complete product page before ordering.