$223.56

3/4 dia. x 12 inch insertion (12.37 OAL) 240V 2500W with 26 inch swaged-in leads and a stainless steel flange.

Diameter
0.75 in
Length
12 in
Voltage
240 V
Wattage
2500 W
Termination
Stainless Steel Flange

Custom heaters are non-returnable.

Looking for a different size?

Step 1
Step 2
Step 3
Step 4
Step 5
Step 6

Cartridge heater 3/4 dia. x 12 inch insertion (12.37 OAL) 240V 2500W with 26 inch swaged in leads ss flange.

Verified specifications

Manufacturer Protherm
Manufacturer Part Number TD75120F-26F
Construction TD
Sheath Material 304SS
Lead Length 26 in
Lead Insulation fiberglass
Lead Covering none

Engineering reference

Cartridge Heater Technical Guide

Installation, watt density, materials, terminations, and controls
1. Tolerance

Standard Specifications & Tolerances

Minimum and maximum diameters are in inches. Lead wire sizes are AWG.

Cartridge Heater Standard Specifications
Nominal DiameterMinimum Diameter (in)Maximum Diameter (in)Standard Lead Wire (AWG)Max. Amps with Standard LeadMax. Lead Wire Size (AWG)Maximum AmpsMaximum Volts
1/8 in.119.124243.6243.6240
1/4 in.244.249246229300
6.5 mm.250.255246229300
5/16 in.306.311246229300
8 mm.309.314246229300
3/8 in.369.3742291815480
10 mm.388.3932291815480
12 mm.466.4712291815480
12.5 mm.486.4912291815480
1/2 in.494.4992291815480
13 mm.506.5112291815480
17/32 in.525.5302291815480
14 mm.545.55018151426480
5/8 in.619.62418151426480
16 mm.624.62918151426480
17 mm.663.66818151426480
11/16 in.682.68718151426480
19 mm.742.74718151426480
3/4 in.744.74918151426480
25 mm.978.98318151426480
1 in.994.99918151426480
  • Length Tolerance: ±3/32 in or ±3%, whichever is greater. See Length & Unheated Section for length-control considerations.
  • Camber Tolerance: 0.025 in per foot of length. Slight camber is normally not a problem because the heater will flex enough to enter a clean hole.
  • Wattage Tolerance: +5%, −10%.
2. Installation & Hole Fit
Tighter hole fit improves heat transfer.

A loose fit creates a larger thermal gap, which reduces heat transfer and can shorten heater life.

Clearance = hole diameter − heater diameter

Clearance is the difference between the finished hole diameter and the actual heater diameter. Evaluate fit and watt density together; an acceptable watt density depends partly on how effectively heat moves into the workpiece.

3. Watt Density

Watt density describes the heater load over its heated sheath area. Use heated length—not necessarily overall or insertion length—when confirmed for the design.

Watt Density = Wattage ÷ (Heated Length × Diameter × 3.14)

Maximum Watt Density for Heating Metals (W/in²)
Hole clearance (in)1200°F1000°F800°F600°F400°F200°F
0.002140270300300300300
0.003120205295300300300
0.004100175240300300300
0.00590145200285300300
0.00770100150200250300
0.0106090110150200225
0.015507595110140165
0.03040608090100110
0.060304050556565
0.100253545505050

Values are application guidelines. Proper heater sizing depends on fit, operating temperature, cycling, and the heated material.

4. Lead / Termination Options

Termination choice affects routing, abrasion resistance, flexing, temperature exposure, and the unheated lead-end region.

Representative product images are shown. The finished heater may not look exactly like the image because dimensions and construction vary by configuration.

Straight swaged leads

Straight swaged leads

Useful where leads may move or must bend sharply near the heater exit.

Right-angle leads

Right-angle leads

Useful where installation and routing space is limited.

Straight stainless braid

Straight stainless braid

Provides abrasion protection while allowing a tighter bend radius than flexible conduit.

Right-angle stainless braid

Right-angle stainless braid

Combines braid protection with compact routing.

Stainless flexible conduit

Stainless flexible conduit

Provides increased abrasion and mechanical protection, with less flexibility than braid.

Right-angle flexible conduit

Right-angle flexible conduit

Combines compact routing with increased mechanical protection.

Lead protection length

Conduit and braid are supplied 2" shorter than the selected lead length.

Crimped-on leads

Crimped-on leads keep lead-end unheated length small for high-temperature exits, but are less suitable for repeated flexing or sharp bends near the heater.

Convoluted conduit and other special protection can be specified for relevant custom applications; continuous flexing still requires engineering review.

5. Choosing a Sheath Material

304 Stainless Steel

The standard choice for oxidation resistance in many applications. Consider Incoloy for service above 1200°F.

316 Stainless Steel

Often preferred for immersion service, particularly tap water, and other environments needing improved corrosion resistance.

Incoloy

Recommended for higher-temperature service above 1200°F. Below that temperature it may not improve performance.

This is application guidance, not a universal chemical-compatibility guarantee.

Sheath suitability and application guidance
Application304 SS316 SSIncoloyMax W/in²Max °F
Air to 1500°FExcellentExcellentExcellent
Air to 1600°FGoodGoodExcellent
Air to 1800°FNot recommendedNot recommendedGood
Acetic acidFairGoodFair40180
AcetoneExcellentExcellentExcellent20130
AlcoholFairExcellentExcellent25212
AsphaltExcellentExcellentExcellent4–10200–500
Caustic soda, 10%ExcellentExcellentExcellent100210
Ethylene glycolFairFairFair30
GlycerinExcellentExcellentExcellent10500
Nitric acid, 30% maxFairFairNot recommended20167
Oil, SAE 30ExcellentExcellentExcellent20250
Oil, SAE 50ExcellentExcellentExcellent10–15250
Steam at 300°FExcellentExcellentExcellent30300
Steam at 500°FExcellentExcellentExcellent25500
Water, distilledExcellentExcellentExcellent300212
Water, tapFairExcellentExcellent300212
6. Fittings & Flanges
Cartridge heater with a brass NPT fittingAFitting lengthB
Single-ended brass NPT fitting — A/B reference
Cartridge heater with a welded two-hole flange
Welded two-hole flange reference

Representative product images. Actual proportions vary with heater diameter, fitting size, and flange dimensions.

This product uses a flange welded at the lead end. Confirm flange diameter, hole spacing, hole size, and location before ordering.

Single-ended NPT fittings
Heater diameter1/4 in3/8 in1/2 in5/8 in3/4 in1 in
NPT thread1/81/43/81/23/41
Brass A.57.70.74.80.921.30
Brass B.43.56.69.871.061.44
Stainless A.62.76.77.84.961.27
Stainless B.46.56.67.871.061.37
Double-ended NPT fittings
Heater diameter1/4 in3/8 in1/2 in5/8 in3/4 in1 in
NPT thread1/81/43/81/23/41
Brass A.981.131.251.531.722.35
Brass B.43.56.69.871.061.37
Stainless A.981.131.251.531.72Call
Stainless B.43.56.68.871.06Call
Standard flange dimensions
Flange ODCompatible heater diametersHole spacingHole size
1 in1/4, 5/16, 3/8, 1/2 in3/4 in.14 in
1-1/2 in1/4, 5/16, 3/8, 1/2, 5/8, 3/4 in1-1/8 in.16 in
2 in1/2, 5/8, 3/4, 1 in1-1/2 in.20 in
7. Length & Unheated Section

Always distinguish insertion length from overall length. Many terminations also require an unheated lead-end section; right-angle styles add an extension beyond the heater body.

Swaged-in leads
Swaged-in leads — unheated lead-end length (in)
Heater length1/4 in5/16 in3/8 in1/2 in5/8 in3/4 in1 in
Under 3 in.20.20.25.30.39.39.61
Over 3 in.81.79.84.841.011.001.27
Crimped-on leads
Crimped-on leads — unheated lead-end length (in)
Heater length1/4 in5/16 in3/8 in1/2 in5/8 in3/4 in1 in
Under 3 in.20.20.25.29.54.54.74
Over 3 in.20.20.25.29.54.54.81
Right-angle leads
Right-angle leads — unheated lead-end length (in)
Heater length1/4 in5/16 in3/8 in1/2 in5/8 in3/4 in1 in
Under 3 in.20.20.25.29.39.39.24
Over 3 in.81.79.84.841.011.00.31
Extension length.25.25.31.37.37.37.75
Straight stainless braid
Straight stainless braid — unheated lead-end length (in)
Heater length1/4 in5/16 in3/8 in1/2 in5/8 in3/4 in1 in
Under 3 in.25.20.35.29.39.39.54
Over 3 in.86.79.94.841.011.001.20
Right-angle stainless braid
Right-angle stainless braid — unheated lead-end length (in)
Heater length1/4 in5/16 in3/8 in1/2 in5/8 in3/4 in1 in
Under 3 in.20.20.25.29.39.39.24
Over 3 in.81.79.84.841.011.00.31
Extension length.31.31.37.37.44.44.75
Straight flexible conduit
Straight flexible conduit — unheated lead-end length (in)
Heater length1/4 in5/16 in3/8 in1/2 in5/8 in3/4 in1 in
Under 3 in.62.60.30.23.39.39.54
Over 3 in1.231.20.89.841.011.001.20
Conduit OD.25.303.303.303.37.48.48
Right-angle flexible conduit
Right-angle flexible conduit — unheated lead-end length (in)
Heater length1/4 in5/16 in3/8 in1/2 in5/8 in3/4 in1 in
Under 3 in.55.60.65.70.90.80.24
Over 3 in.81.79.84.841.011.00.31
Extension length.31.37.37.37.44.44.75
Conduit OD.25.25.33.37.37.37.37

Cartridge Heater Length & Tolerance

Swaging reduces heater diameter and causes predictable but variable length growth. Longer heaters can need special consideration. Standard trimming can remove only unheated portions, so an exact finished length may require a designed cold section or a custom length-control construction. Contact engineering for unusual length, flange-location, or minimal-unheated-section requirements.

8. Temperature Control

Appropriate temperature control reduces overheating risk and unnecessary cycling. Match the controller, power switching, sensor, voltage, current, and control method to the application.

9. Thermocouple / Sensor Selection

Need Temperature Feedback?

Measure the controlled process

Cartridge-heater systems commonly use a thermocouple or another temperature sensor. A separate sensor measures the process unless the heater was specifically designed with an internal thermocouple.

Shop Thermocouples
10. Extending Heater Life
  • Keep contaminants, adhesives, grease-based compounds, and other carbon-forming materials away from the lead entrance.
  • Use the tightest practical, clean, straight hole fit specified for the design.
  • Avoid unnecessary cycling and do not apply more wattage than the process requires.
  • Use appropriate temperature control and confirm the sensor represents the controlled process.
  • Protect leads from abrasion, excessive bending, and movement with the correct termination.
11. Frequently Asked Questions
How long will a cartridge heater last?

There is no single standard life. Service life depends on the application, operating temperature, watt density, cycling, hole fit, and contamination.

What is the maximum operating temperature?

The appropriate limit depends on the sheath material and application conditions. Select the sheath for the process environment and obtain engineering review for high-temperature or corrosive service.

What determines maximum watt density?

The heated material, application temperature, and hole fit all affect allowable watt density. A tighter fit generally improves heat transfer; watt density and fit must be evaluated together.

How much does a cartridge heater expand when heated?

Thermal expansion is usually not a primary fit issue because the heated part expands too. Allowance may still be important in constrained assemblies or unusual materials, so consult engineering when movement is critical.

How can I extend cartridge heater life?

Prevent contamination at the lead end, avoid unnecessary cycling, size the heater correctly, avoid excess wattage, maintain proper hole fit, and use appropriate temperature control.

Should I use temperature control?

Proper temperature control helps reduce overheating and excessive cycling. The controller, sensor, voltage, current, and control method must all suit the application.

Cartridge Heater Selection

Similar cartridge heaters

Explore nearby catalog products. Each card shows only what changes from the heater above; confirm the complete product page before ordering.