PVC & PEX Pipe - Heat Trace Cable
Browse heat-trace cable intended for freeze protection of PVC and PEX water piping. Select a listed cable for the actual pipe material, insulation, temperature, voltage, and installation conditions.
Follow the selected cable instructions for plastic-pipe installation, attachment, controls, and insulation. For water-pipe system selection, use the Pipe Freeze Protection Configurator.
Compare the cables below, or read the PVC/PEX selection and installation guide before choosing a cable system.
Showing all 16 results
-

3 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – TPE Overjacket – 2700 Series
SKU 2703-11R00
PVC & PEX compatible$5.65 per ft View Product -

3 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – TPE Overjacket – 2700 Series
SKU 2703-21R00
PVC & PEX compatible$5.65 per ft View Product -

3 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – Tinned Copper Braid + Fluoropolymer Outer Jacket – 2700 Series
SKU 2703-11T00
PVC & PEX compatible$7.45 per ft View Product -

3 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – Tinned Copper Braid + Fluoropolymer Outer Jacket – 2700 Series
SKU 2703-21T00
PVC & PEX compatible$7.45 per ft View Product -

5 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – TPE Overjacket – 2700 Series
SKU 2705-11R00
PVC & PEX compatible$5.65 per ft View Product -

5 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – TPE Overjacket – 2700 Series
SKU 2705-21R00
PVC & PEX compatible$5.65 per ft View Product -

5 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – Tinned Copper Braid + Fluoropolymer Outer Jacket – 2700 Series
SKU 2705-11T00
PVC & PEX compatible$7.45 per ft View Product -

5 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – Tinned Copper Braid + Fluoropolymer Outer Jacket – 2700 Series
SKU 2705-21T00
PVC & PEX compatible$7.45 per ft View Product -

3 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – Thermoplastic Overjacket over Metal Braid – HTR
SKU 3HTR1-CR
PVC & PEX compatible$5.42 per ft View Product -

3 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – Thermoplastic Overjacket over Metal Braid – HTR
SKU 3HTR2-CR
PVC & PEX compatible$5.42 per ft View Product -

3 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – Fluoropolymer Overjacket over Metal Braid – HTR
SKU 3HTR1-CT
PVC & PEX compatible$7.41 per ft View Product -

3 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – Fluoropolymer Overjacket over Metal Braid – HTR
SKU 3HTR2-CT
PVC & PEX compatible$7.41 per ft View Product -

5 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – Thermoplastic Overjacket over Metal Braid – HTR
SKU 5HTR1-CR
PVC & PEX compatible$5.42 per ft View Product -

5 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – Thermoplastic Overjacket over Metal Braid – HTR
SKU 5HTR2-CR
PVC & PEX compatible$5.42 per ft View Product -

5 Watt per Foot 120 Volt Self-Regulating Heat Trace Cable – Fluoropolymer Overjacket over Metal Braid – HTR
SKU 5HTR1-CT
PVC & PEX compatible$7.41 per ft View Product -

5 Watt per Foot 240 Volt Self-Regulating Heat Trace Cable – Fluoropolymer Overjacket over Metal Braid – HTR
SKU 5HTR2-CT
PVC & PEX compatible$7.41 per ft View Product
Selecting heat trace for PVC and PEX water pipes
External heat tracing helps protect water piping from freezing when the cable, pipe, insulation and controls are selected as a system. Plastic transfers heat less readily than metal, so a metal-pipe selection should not be assumed to suit PVC or PEX.
Confirm pipe and cable compatibility
Check that both manufacturers permit the proposed heat-trace installation on the exact pipe material and service. Keep the design within the pipe's applicable temperature limits. A cable's maximum maintenance or exposure temperature is a cable rating, not an allowable PVC or PEX pipe temperature.
Compare the 2700 Series data sheet (PDF) and HTR data sheet (PDF) for cable construction and ratings.
Choose output and supply voltage
This category offers 3 and 5 W/ft cable, nominally rated at 50°F (10°C), in separate 120 V and 240 V versions. Examples include 3 W/ft 120 V 2700 Series cable and 5 W/ft 240 V HTR cable. Match the exact part to the available supply.
Self-regulating output changes with temperature. Required output and run layout depend on pipe size, minimum ambient temperature and insulation; these two output choices do not cover every installation. Use the selected family's circuit table for maximum length, breaker and startup conditions.
Plan attachment and insulation together
Size for the insulation type and thickness that will actually be installed. Include fittings, valves and exposed sections in the design, and follow the insulation instructions for weather protection.
Use an attachment and heat-spreading method permitted by both the pipe and cable instructions. Aluminum tape is appropriate only where specified and permitted; some PEX manufacturers require ties instead of tape. If the instructions differ, request application review before installation.
Specify protection and temperature control
Provide the specified braid grounding, overcurrent protection and ground-fault equipment protection. An ordinary circuit breaker does not replace ground-fault protection. Check whether the selected controller includes it or needs a separate ground-fault protection unit.
Ambient sensing responds to air temperature; line sensing monitors the pipe. Select the sensing arrangement, setpoint and electrical ratings for the pipe system. Compare heat-trace controls; self-regulation does not replace required thermostatic control.
Match connection kits to the cable family
Power connections, end seals and splice or tee kits perform different jobs. Match each kit's stated cable family, sealing parts and installation rating to the selected cable and jacket.
Review the SLCAB connection kit, HTR low-profile end seal and HTR inline splice kit documentation for their stated applications. They are not blanket substitutes for one another. Count power feeds, cable ends and branches, and confirm what each package includes.
Use the configurator before selecting cable
For water-pipe freeze protection, use the Pipe Freeze Protection Configurator with the pipe material and diameter, pipe length, lowest ambient temperature, insulation thickness and supply voltage. It helps review supported cable and circuit arrangements and system components.
For conditions outside its supported choices or conflicting manufacturer instructions, request application help. The Heat Tape or Heat Trace guide explains the differences between these product types.
Complete the Cable System
Choose power connections, end seals, installation accessories and controls specified for the selected cable family. Check each component's supported cable type, electrical ratings and installation requirements before ordering.
Connection and installation accessories
Heat Trace Power / End Seal Junction Box With LightPart Number: PTBS-L-GET
Silicone Core Sealer For Heat Trace CablePart Number: SLP
Power Connection KitPart Number: PT-PTBS-GET
Multi Power Connection KitPart Number: PT-PTBS-GET-3
Low-Profile Tee Splice Connection KitPart Number: PT-JHT-GET
Low-Profile Inline Splice Connection KitPart Number: PT-JHS-GET
Low-Profile End Seal KitPart Number: PT-JHE-GET
10 Piece Heat Trace Cable End Seal KitPart Number: SLCABKC
3 Piece Heat Trace Cable End Seal KitPart Number: SLCABKC-3
End-of-Circuit Heat Trace Monitor Light Kit – GreenPart Number: PTJHE-L-GREEN
End-of-Circuit Heat Trace Monitor Light Kit – RedPart Number: PTJHE-L-RED
JBS-SPA Small Pipe Adaptor For Pipe StandoffPart Number: JBS-SPA
Low Temp Heat Trace Cable Connection KitPart Number: SLCABUC
10 Piece Heat Trace Cable Input Connections or Tee SplicesPart Number: SLCABSK
Standoff Power Connection Kit With Junction Box - MetalPart Number: PCK-M
Standoff Tee Splice Kit With Junction Box - MetalPart Number: STK-M
Ground Fault Protection Unit - Required By ULPart Number: GF
Metal Double Hub Junction/Conduit BoxPart Number: JBM002
Metal Single Hub Junction/Conduit BoxPart Number: JBM001
Pipe Reducer Adapts 0.75" NPT Male To 1" NPT FemalePart Number: BPRCAB010
Pipe Standoff for Heat Cable with 1-Inch ThreadPart Number: PSOCAB010
Pipe Standoff for Heat Cable with 3/4 Inch ThreadPart Number: PSOCAB075
RTV Silicone SealantPart Number: RTV
Aluminum Tape 2.83" x 150' 500 DegreesPart Number: PT14
UL Power Connection With Ground Fault Kit For Heat Trace CablePart Number: JSR08
Fiberglass Tape 0.5" x 98' 350 DegreesPart Number: P212
Heat Trace Caution Labels 10 PackPart Number: PTHTCL
Thermostats and controllers
Choose ambient or line sensing and confirm voltage, circuit load, sensor, enclosure, and ground-fault requirements.
Single Point Freeze Protection Heat Trace ControllerPart Number: FPT-130
Single Point General Purpose Heat Trace ControllerPart Number: GPT-130
Dual Point General Purpose Heat Trace ControllerPart Number: GPT-230
S1-B-2002 Heat Trace Controller - Thermistor only, No RTD, No ModbusPart Number: S1-B-2002
S1-A Heat Trace Controller - RTD & Thermistor With Modbus and BACnet CompatibilityPart Number: S1-A
HTP30 Basic Heat Trace Control Panel With GFIPart Number: HTP30
Ambient Sensing Thermostat NEMA 4XPart Number: 1660-18911
Line Sensing Thermostat NEMA 4XPart Number: 1660-13A11