Low-Profile End Seal Kit
CSA End Seal Kit Provides end seal connection for low and mid-temp, self-regulating heat trace cables.
Enough to complete one end seal connection.
For use in hazardous area locations with low and mid-temp cable only (CSA approved).
For use in non-hazardous area locations with low and mid-temp cable (non-CSA approved).
Our CSA rated end seal kit provides end seal connection for low and mid-temp, self-regulating heat trace cables.
Enough to complete one end seal connection.
Ordinary Locations
Hazardous Location
T6 rated 3, 5, 8, 19 W/ft (10, 17, 25, 31 W/m)
T5 rated 12 W/ft (40 W/m)
Class I Division 2 Groups A, B, C, D
Class II Division 2 Groups E, F, G
Class III
Designed to provide a long and efficient service life with function, reliability, and safety in mind.
Durable corrosion-resistant enclosures provide premium protection for electrical end seal.
Approved for use in non-hazardous area (ordinary) locations with HTR, HTS, HTP series heating cable.
Approved for use in hazardous area (Class Ⅰ, Div 2; Class Ⅱ, Div2; Class Ⅲ) locations with HTR series heating cable only.
Installed on the pipe under insulation and/or cladding.
Rated NEMA 4X.
Specifications
Maximum current: 32A
Voltage: 110-120V, 208-277V
Maximum Continuous Exposure Temperature (T5): 212℉(100℃)